539 lines
17 KiB
Plaintext
539 lines
17 KiB
Plaintext
|
; PSI Config File
|
||
|
;
|
||
|
; @category PHP
|
||
|
; @package PSI
|
||
|
; @author Michael Cramer <BigMichi1@users.sourceforge.net>
|
||
|
; @copyright 2009 phpSysInfo
|
||
|
; @license http://opensource.org/licenses/gpl-2.0.php GNU General Public License
|
||
|
; @version SVN: $Id: phpsysinfo.ini.new 705 2012-11-11 00:33:29Z namiltd $
|
||
|
; @link http://phpsysinfo.sourceforge.net
|
||
|
|
||
|
[main]
|
||
|
; ********************************
|
||
|
; MAIN PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
; Turn on debugging of some functions and include errors and warnings in xml and provide a popup for displaying errors
|
||
|
; - false : no debug information are stored in xml or displayed
|
||
|
; - true : debug information stored in xml and displayed *be careful if set this to true, may include sensitive information from your pc*
|
||
|
;
|
||
|
DEBUG=false
|
||
|
|
||
|
; Turn on logging/unlogging of functions executeProgram() and rfts()
|
||
|
; example : executeProgram () and rfts () record the results to the "/tmp/phpsysinfo.log" file
|
||
|
; LOG="/tmp/phpsysinfo.log"
|
||
|
; example : executeProgram () and rfts () read the results from the "/tmp/phpsysinfo.log" file
|
||
|
; LOG="-/tmp/phpsysinfo.log"
|
||
|
; example : executeProgram () and rfts () read the results from the "/tmp/phpsysinfo.log" file
|
||
|
; LOG="+/tmp/phpsysinfo.log", if lack in the log file it runs normally
|
||
|
;
|
||
|
LOG=false
|
||
|
|
||
|
; Turn on/off compression for JavaScript file
|
||
|
; - JS_COMPRESSION=false //no compression (recommended with slow processor)
|
||
|
; - JS_COMPRESSION="None" //code minimizing
|
||
|
; - JS_COMPRESSION="Normal" //code packing
|
||
|
;
|
||
|
JS_COMPRESSION="Normal"
|
||
|
|
||
|
; Additional paths where to look for installed programs
|
||
|
; Example : ADD_PATHS="/opt/bin,/opt/sbin"
|
||
|
;
|
||
|
ADD_PATHS=false
|
||
|
|
||
|
; Plugins that should be included in xml and output
|
||
|
; List of plugins should look like "plugin,plugin,plugin". See /plugins directory
|
||
|
; - PLUGINS="MDStatus,PS" //list of plugins
|
||
|
; - PLUGINS=false //no plugins
|
||
|
; included plugins:
|
||
|
; - MDStatus - show the raid status and whats currently going on
|
||
|
; - DMRaid - show the software raid status
|
||
|
; - PS - show a process tree of all running processes
|
||
|
; - PSStatus - show a graphical representation if a process is running or not
|
||
|
; - Quotas - show a table with all quotas that are active and there current state
|
||
|
; - SMART - show S.M.A.R.T. information from drives that support it
|
||
|
; - BAT - show battery state on a laptop
|
||
|
; - IPMIInfo - show IPMI status
|
||
|
; - UpdateNotifier - show update notifications (only for Ubuntu server)
|
||
|
; - SNMPPInfo - show printers info via SNMP
|
||
|
; - Uprecords - show uprecords info
|
||
|
;
|
||
|
PLUGINS='MDStatus,PS,DMRaid,PSStatus,Quotas,SMART'
|
||
|
|
||
|
|
||
|
; ********************************
|
||
|
; DISPLAY PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
|
||
|
; Define the default display mode
|
||
|
; auto: let user browser choose the mode
|
||
|
; dynamic: use javascript to refresh data
|
||
|
; static: static page (use metatag to reload page)
|
||
|
; bootstrap: use twitter bootstrap template
|
||
|
;
|
||
|
DEFAULT_DISPLAY_MODE="auto"
|
||
|
|
||
|
|
||
|
; Define the default language
|
||
|
;
|
||
|
DEFAULT_LANG="en"
|
||
|
|
||
|
|
||
|
; Define the default template
|
||
|
;
|
||
|
DEFAULT_TEMPLATE="phpsysinfo"
|
||
|
|
||
|
|
||
|
; Show or hide language picklist
|
||
|
;
|
||
|
SHOW_PICKLIST_LANG=true
|
||
|
|
||
|
|
||
|
; Show or hide template picklist
|
||
|
;
|
||
|
SHOW_PICKLIST_TEMPLATE=true
|
||
|
|
||
|
|
||
|
; Show CPU list expanded
|
||
|
;
|
||
|
SHOW_CPULIST_EXPANDED=true
|
||
|
|
||
|
|
||
|
; Show CPU info expanded
|
||
|
;
|
||
|
SHOW_CPUINFO_EXPANDED=false
|
||
|
|
||
|
|
||
|
; Define the interval for refreshing data in ms
|
||
|
; - 0 : disabled
|
||
|
; - 1000 : 1 second
|
||
|
; Default is 60 seconds
|
||
|
;
|
||
|
REFRESH=60000
|
||
|
|
||
|
|
||
|
; Show a graph for current cpuload
|
||
|
; - true : displayed, but it's a performance hit (because we have to wait to get a value, 1 second)
|
||
|
; - false : will not be displayed
|
||
|
;
|
||
|
LOAD_BAR=false
|
||
|
|
||
|
|
||
|
; Display the virtual host name and address
|
||
|
; - Default is canonical host name and address
|
||
|
; - Use USE_VHOST=true to display virtual host name.
|
||
|
;
|
||
|
USE_VHOST=false
|
||
|
|
||
|
|
||
|
; Controls the units & format for network, memory and filesystem
|
||
|
; - 1 KiB = 2^10 bytes = 1,024 bytes
|
||
|
; - 1 KB = 10^3 bytes = 1,000 bytes
|
||
|
; - "B" everything is in Byte
|
||
|
; - "PiB" everything is in PeBiByte
|
||
|
; - "TiB" everything is in TeBiByte
|
||
|
; - "GiB" everything is in GiBiByte
|
||
|
; - "MiB" everything is in MeBiByte
|
||
|
; - "KiB" everything is in KiBiByte
|
||
|
; - "auto_binary" everything is automatic done if value is to big for, e.g MiB then it will be in GiB
|
||
|
; - "PB" everything is in PetaByte
|
||
|
; - "TB" everything is in TeraByte
|
||
|
; - "GB" everything is in GigaByte
|
||
|
; - "MB" everything is in MegaByte
|
||
|
; - "KB" everything is in KiloByte
|
||
|
; - "auto_decimal" everything is automatic done if value is to big for, e.g MB then it will be in GB
|
||
|
;
|
||
|
BYTE_FORMAT="auto_binary"
|
||
|
|
||
|
|
||
|
; Format in which temperature is displayed
|
||
|
; - "c" shown in celsius
|
||
|
; - "f" shown in fahrenheit
|
||
|
; - "c-f" both shown first celsius and fahrenheit in braces
|
||
|
; - "f-c" both shown first fahrenheit and celsius in braces
|
||
|
;
|
||
|
TEMP_FORMAT="c"
|
||
|
|
||
|
|
||
|
; ********************************
|
||
|
; SENSORS PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
|
||
|
; Define the motherboard monitoring program
|
||
|
; We support the following programs so far
|
||
|
; - LMSensors http://www.lm-sensors.org/ (Linux)
|
||
|
; - Healthd http://healthd.thehousleys.net/ (FreeBSD)
|
||
|
; - HWSensors http://www.openbsd.org/ (OpenBSD)
|
||
|
; - MBMon http://www.nt.phys.kyushu-u.ac.jp/shimizu/download/download.html (FreeBSD/Linux/NetBSD/OpenBSD)
|
||
|
; - MBM5 http://mbm.livewiredev.com/ (WinNT)
|
||
|
; - Coretemp No addon tool neded (FreeBSD)
|
||
|
; - IPMI http://openipmi.sourceforge.net/ (Linux)
|
||
|
; - FreeIPMI http://www.gnu.org/software/freeipmi/ (FreeBSD/Linux/OpenBSD/SunOS)
|
||
|
; - IPMIutil http://ipmiutil.sourceforge.net/ (Darwin/FreeBSD/Linux/SunOS/WinNT)
|
||
|
; - K8Temp http://hur.st/k8temp/ (DragonFly/FreeBSD/NetBSD/OpenBSD)
|
||
|
; - PiTemp No addon tool neded (Raspberry Pi and Banana Pi - Linux)
|
||
|
; - OHM http://openhardwaremonitor.org/ (WinNT)
|
||
|
; - ThermalZone No addon tool neded (WinNT/Linux/Android)
|
||
|
;
|
||
|
; Example: If you want to use lmsensors : SENSOR_PROGRAM="LMSensors"
|
||
|
; If you want to use lmsensors and IPMI: SENSOR_PROGRAM="LMSensors,IPMI"
|
||
|
;
|
||
|
SENSOR_PROGRAM="LMSensors"
|
||
|
|
||
|
|
||
|
; Define how to access the monitor program
|
||
|
; Available methods for the above list are in the following list
|
||
|
; default method "command" should be fine for everybody
|
||
|
; if multiple SENSOR_PROGRAM defined must fit to all
|
||
|
; !!! tcp connections are only made local and on the default port !!!
|
||
|
; - LMSensors command, file
|
||
|
; - Healthd command, file
|
||
|
; - HWSensors (no matter - always command)
|
||
|
; - MBMon command, file, tcp
|
||
|
; - MBM5 (no matter - always file)
|
||
|
; - Coretemp (no matter - always command)
|
||
|
; - IPMI command, file
|
||
|
; - FreeIPMI command, file
|
||
|
; - IPMIutil command, file
|
||
|
; - K8Temp command, file
|
||
|
; - PiTemp (no matter - always command)
|
||
|
; - OHM (no matter - always command)
|
||
|
; - ThermalZone (no matter - always command)
|
||
|
;
|
||
|
SENSOR_ACCESS="command"
|
||
|
|
||
|
; Show events of sensors
|
||
|
; - true : show events
|
||
|
; - false : do not show events
|
||
|
;
|
||
|
SENSOR_EVENTS=true
|
||
|
|
||
|
|
||
|
; Hddtemp program
|
||
|
; If the hddtemp program is available we can read the temperature, if hdd is smart capable
|
||
|
; !!ATTENTION!! hddtemp might be a security issue
|
||
|
; - HDD_TEMP="tcp" //read data from hddtemp deamon (localhost:7634)
|
||
|
; - HDD_TEMP="command" //read data from hddtemp programm (must be set suid)
|
||
|
;
|
||
|
HDD_TEMP=true
|
||
|
|
||
|
|
||
|
; ********************************
|
||
|
; FILESYSTEM PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
|
||
|
; Show mount point
|
||
|
; - true : show mount point
|
||
|
; - false : do not show mount point
|
||
|
;
|
||
|
SHOW_MOUNT_POINT=true
|
||
|
|
||
|
; Show mount option
|
||
|
; - true : show mount option
|
||
|
; - false : do not show mount option
|
||
|
;
|
||
|
SHOW_MOUNT_OPTION=true
|
||
|
|
||
|
|
||
|
; Show mount credentials
|
||
|
; - true : show mount credentials
|
||
|
; - false : do not show mount credentials
|
||
|
;
|
||
|
SHOW_MOUNT_CREDENTIALS=false
|
||
|
|
||
|
|
||
|
; Show inode usage
|
||
|
; - true : display used inodes in percent
|
||
|
; - false : hide them
|
||
|
;
|
||
|
SHOW_INODES=true
|
||
|
|
||
|
|
||
|
; Hide mounts
|
||
|
; Example : HIDE_MOUNTS="/home,/usr"
|
||
|
;
|
||
|
HIDE_MOUNTS=""
|
||
|
|
||
|
|
||
|
; Hide filesystem types
|
||
|
; Example : HIDE_FS_TYPES="tmpfs,devtmpfs,usbfs,bstfolder"
|
||
|
;
|
||
|
HIDE_FS_TYPES=""
|
||
|
|
||
|
|
||
|
; Hide partitions
|
||
|
; Example : HIDE_DISKS="rootfs,/dev/sda1"
|
||
|
; HIDE_DISKS=true //hide all partitions
|
||
|
;
|
||
|
HIDE_DISKS=""
|
||
|
|
||
|
; Filesystem usage warning threshold in percent
|
||
|
; - 0 : disabled
|
||
|
; - 90 : 90%
|
||
|
; Default is 90%
|
||
|
;
|
||
|
FS_USAGE_THRESHOLD=90
|
||
|
|
||
|
|
||
|
; ********************************
|
||
|
; NETWORK PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
|
||
|
; Hide network interfaces
|
||
|
; Example : HIDE_NETWORK_INTERFACE="eth0,sit0"
|
||
|
; HIDE_NETWORK_INTERFACE=true //hide all network interfaces
|
||
|
;
|
||
|
HIDE_NETWORK_INTERFACE=""
|
||
|
|
||
|
|
||
|
; Show network interfaces infos for Linux, Android, FreeBSD, Haiku, Darwin, SunOS, Minix, QNX and WinNT
|
||
|
; Example : SHOW_NETWORK_INFOS=true
|
||
|
;
|
||
|
SHOW_NETWORK_INFOS=true
|
||
|
|
||
|
|
||
|
; ********************************
|
||
|
; UPS PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
|
||
|
; Define the ups monitoring program
|
||
|
; We support the following programs so far
|
||
|
; - 1. Apcupsd http://www.apcupsd.com/
|
||
|
; - 2. Nut http://www.networkupstools.org/
|
||
|
; - 3. PowerSoftPlus http://ever.eu/
|
||
|
; - 4. pmset based on the result of the command "pmset -g batt" on Darwin system
|
||
|
; Example: If you want to use Apcupsd : UPS_PROGRAM="Apcupsd"
|
||
|
; If you want to use Apcupsd and Nut : UPS_PROGRAM="Apcupsd,Nut"
|
||
|
;
|
||
|
UPS_PROGRAM=false
|
||
|
|
||
|
|
||
|
; Apcupsd supports multiple UPSes
|
||
|
; You can specify comma delimited list in the form <hostname>:<port> or <ip>:<port>. The defaults are: 127.0.0.1:3551
|
||
|
; See the following parameters in apcupsd.conf: NETSERVER, NISIP, NISPORT
|
||
|
; It uses the defaults if not specified.
|
||
|
;
|
||
|
UPS_APCUPSD_LIST=false
|
||
|
|
||
|
|
||
|
; Apcupsd has a CGI monitoring utility called apcupsd-cgi
|
||
|
; You can set the parameter below to true if you have it installed - this will add apcupsd-cgi links to the UPS tree
|
||
|
;
|
||
|
UPS_APCUPSD_CGI_ENABLE=false
|
||
|
|
||
|
|
||
|
; Nut supports multiple UPSes
|
||
|
; You can specify comma delimited list in the form <hostname>:<port> or <ip>:<port>. The defaults are: 127.0.0.1:3493
|
||
|
; See the following parameters in upsd.conf: LISTEN
|
||
|
; It uses the defaults if not specified.
|
||
|
;
|
||
|
UPS_NUT_LIST=false
|
||
|
|
||
|
|
||
|
; ********************************
|
||
|
; PLUGINS PARAMETERS
|
||
|
; ********************************
|
||
|
|
||
|
|
||
|
[bat]
|
||
|
; BAT Plugin configuration
|
||
|
|
||
|
; define how to access the battery statistic data
|
||
|
; - "command" read /proc/acpi/battery/BAT0/info and /proc/acpi/battery/BAT0/state
|
||
|
; on newer kernel or on Android read file from /sys/class/power_supply/
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "bat_info.txt" and "bat_state.txt"; content is the output
|
||
|
; from "cat /proc/acpi/battery/BAT0/info" and "cat /proc/acpi/battery/BAT0/state")
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
; define the battery device (no matter for WinNT, FreeBSD, Darwin and some Android and Linux)
|
||
|
;
|
||
|
DEVICE="BAT0"
|
||
|
|
||
|
|
||
|
[ipmiinfo]
|
||
|
; ipmiinfo Plugin configuration
|
||
|
|
||
|
; define how to access the IPMI statistic data
|
||
|
; - "command" ipmitool command is run everytime the block gets refreshed or build
|
||
|
; if access error execute first: chmod 666 /dev/ipmi0
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "ipmiinfo.txt"; content is the output from "ipmitool sensor")
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
|
||
|
[mdstatus]
|
||
|
; MDStatus Plugin configuration
|
||
|
|
||
|
; define how to access the mdstat statistic data
|
||
|
; - "file" /proc/mdstat is read
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "mdstat.txt"; content is the output from "cat /proc/mdstat")
|
||
|
;
|
||
|
ACCESS="file"
|
||
|
|
||
|
; Hide RAID devices
|
||
|
; Example : HIDE_RAID_DEVICES="md127"
|
||
|
;
|
||
|
HIDE_RAID_DEVICES=""
|
||
|
|
||
|
|
||
|
[dmraid]
|
||
|
; DMRaid Plugin configuration
|
||
|
|
||
|
; define how to access the dmraid statistic data
|
||
|
; - "command" dmraid command is run everytime the block gets refreshed or build
|
||
|
; if access error try execute first: chmod 4755 /sbin/dmraid
|
||
|
; This method is not recommended for safety reasons!
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "dmraid.txt"; content is generated by command "dmraid -s -vv >dmraid.txt 2>&1")
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
; Hide RAID devices
|
||
|
; Example : HIDE_RAID_DEVICES=".ddf1_disks"
|
||
|
;
|
||
|
HIDE_RAID_DEVICES=""
|
||
|
|
||
|
|
||
|
[ps]
|
||
|
; PS Plugin configuration
|
||
|
|
||
|
; define how to access the ps statistic data
|
||
|
; - "command" ps command is run everytime the block gets refreshed or build / on WINNT
|
||
|
; information is retrieved everytime through WMI
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "ps.txt"; content is the output from "ps -axo pid,ppid,pmem,args")
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
; Show kthreadd child list expanded
|
||
|
;
|
||
|
SHOW_KTHREADD_EXPANDED=true
|
||
|
|
||
|
|
||
|
[psstatus]
|
||
|
; PSStatus Plugin configuration
|
||
|
|
||
|
; define how to access the psstatus statistic data
|
||
|
; - "command" pidof command is run everytime the block gets refreshed or build / on WINNT
|
||
|
; information is retrieved everytime through WMI
|
||
|
; - "data" a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "psstatus.txt"; content is the output from
|
||
|
; <code>for ps in "apache2" "mysqld" "sshd"; do echo $ps "|" `pidof -s $ps`; done</code>
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
; Regular expression search in the process name (e.g. "ddclient.*")
|
||
|
; - true : Regular expression search (used pgrep command)
|
||
|
; - false : Normal search (used pidof command)
|
||
|
;
|
||
|
USE_REGEX=false
|
||
|
|
||
|
; controls which processes are checked if they are running
|
||
|
;
|
||
|
; string contains a list of process names that are checked, names are seperated by a comma (on WINNT names must end with '.exe')
|
||
|
;
|
||
|
PROCESSES="mysqld, sshd, explorer.exe"
|
||
|
|
||
|
|
||
|
[quotas]
|
||
|
; Quotas Plugin configuration
|
||
|
;
|
||
|
; define how to access the repquota statistic data
|
||
|
; - "command" repquota command is run everytime the block gets refreshed or build
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation with the filename "quotas.txt"; content is the output from "repquota -au")
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
|
||
|
[smart]
|
||
|
; SMART Plugin configuration
|
||
|
|
||
|
; Smartctl program
|
||
|
; If the smartctl program is available we can read S.M.A.R.T informations
|
||
|
; - "command" smartctl command is run everytime the block gets refreshed or build
|
||
|
; if error: Smartctl open device: /dev/sda failed: Permission denied
|
||
|
; Not recommended method:
|
||
|
; execute: chmod 4755 /usr/sbin/smartctl
|
||
|
; - "data" (a file must be available in the data directory of the
|
||
|
; phpsysinfo installation with the filename "smart{disk_number}.txt";
|
||
|
; content is the output from "smartctl --all device")
|
||
|
;
|
||
|
ACCESS="command"
|
||
|
|
||
|
; Smartctl devices to monitor
|
||
|
; If the smartctl support is enabled, those disks information will be displayed
|
||
|
; - DEVICES="/dev/hda,/dev/hdb" //Will display those two disks informations
|
||
|
; You also can specify --device option value for smartctl command surrounded by parentheses eg:
|
||
|
; - DEVICES="(marvell)/dev/sda"
|
||
|
; or
|
||
|
; - DEVICES="(megaraid.0)/dev/sda" //comma in --device option value is replaced by a dot
|
||
|
;
|
||
|
DEVICES="/dev/sda, /dev/sdb"
|
||
|
|
||
|
; Smartctl ID# and column name from "Vendor Specific SMART Attributes with Thresholds" table
|
||
|
; If the smartctl support is enabled, enter the ID#-COLUMN_NAME from "Vendor Specific SMART Attributes with Thresholds" table from smartctl output.
|
||
|
; or for no SCSI devices: ID#-COLUMN_NAME-REPLACEMENT_ID# where REPLACEMENT_ID# is an alternative ID number.
|
||
|
; COLUMN_NAME of this ID# will be displayed in the phpsysinfo S.M.A.R.T table. If you want RAW_VALUE to be displayed for the temperature (ID# 194) enter 194-RAW_VALUE
|
||
|
; - IDS="194-VALUE,4-VALUE,009-RAW_VALUE" //ID#-COLUMN_NAME, ID#-COLUMN_NAME, etc...
|
||
|
;
|
||
|
IDS="005-RAW_VALUE,194-RAW_VALUE,4-RAW_VALUE,009-RAW_VALUE,012-RAW_VALUE,193-RAW_VALUE-225,001-RAW_VALUE,007-RAW_VALUE,200-RAW_VALUE,197-RAW_VALUE,198-RAW_VALUE"
|
||
|
|
||
|
|
||
|
[snmppinfo]
|
||
|
; SNMPPInfo Plugin configuration
|
||
|
|
||
|
; define how to access the SNMP Printer Info statistic data
|
||
|
; - "php-snmp" execute php snmprealwalk function (php-snmp module must be installed)
|
||
|
; - "command" execute snmpwalk command
|
||
|
; - "data" a file must be available in the data directory of the
|
||
|
; phpsysinfo installation with the filename "snmppinfo{printer_number}.txt";
|
||
|
; content is the output from:
|
||
|
; snmpwalk -On -c public -v 1 {printer_address} .1.3.6.1.2.1.1.5 > snmppinfo{printer_number}.txt
|
||
|
; snmpwalk -On -c public -v 1 {printer_address} .1.3.6.1.2.1.43.11.1.1 >> snmppinfo{printer_number}.txt
|
||
|
; snmpwalk -On -c public -v 1 {printer_address} .1.3.6.1.2.1.43.18.1.1 >> snmppinfo{printer_number}.txt
|
||
|
;
|
||
|
ACCESS="php-snmp"
|
||
|
|
||
|
;define the Printer devices
|
||
|
;
|
||
|
; string contains a list of printer addresses that are checked
|
||
|
;
|
||
|
DEVICES="192.168.0.5, 192.168.0.9"
|
||
|
|
||
|
|
||
|
[updatenotifier]
|
||
|
; Update Notifier Plugin configuration
|
||
|
|
||
|
; define the update info file format
|
||
|
; - true: Ubuntu Landscape format (file: /var/lib/update-notifier/updates-available)
|
||
|
; - false: universal format (format: A;B)
|
||
|
; A: total packages to update
|
||
|
; B: security packages to update
|
||
|
;
|
||
|
UBUNTU_LANDSCAPE_FORMAT=true
|
||
|
|
||
|
; define the update info file
|
||
|
;
|
||
|
FILE="/var/lib/update-notifier/updates-available"
|
||
|
|
||
|
[uprecords]
|
||
|
; Uprecords Plugin configuration
|
||
|
|
||
|
; define how to access the uprecords statistic data
|
||
|
; - "command" uprecords command is run everytime the block gets refreshed or build
|
||
|
; if access error try execute first: chmod 4755 /usr/bin/uprecords
|
||
|
; This method is not recommended for safety reasons!
|
||
|
; - "data" (a file must be available in the data directory of the phpsysinfo installation
|
||
|
; with the filename "uprecords.txt"; content is the output from "env TZ=GMT uprecords -a -w")
|
||
|
;
|
||
|
ACCESS="command"
|