Generating detailed summary of the adapter, it may take a while to complete.
|
||
|
|
||
|
Controller = 0
|
||
|
Status = Success
|
||
|
Description = None
|
||
|
|
||
|
|
||
|
Basics :
|
||
|
======
|
||
|
Controller = 0
|
||
|
Model = LSI 2108 MegaRAID
|
||
|
Serial Number = FW-ABCDEFGHIJKLM
|
||
|
Current Controller Date/Time = 12/24/2022, 10:33:04
|
||
|
Current System Date/time = 12/24/2022, 10:33:22
|
||
|
SAS Address = 5003048014579200
|
||
|
PCI Address = 00:82:00:00
|
||
|
Mfg Date = 00/00/00
|
||
|
Rework Date = 00/00/00
|
||
|
Revision No =
|
||
|
|
||
|
|
||
|
Version :
|
||
|
=======
|
||
|
Firmware Package Build = 12.15.0-0239
|
||
|
Firmware Version = 2.130.403-4660
|
||
|
Bios Version = 3.30.02.2_4.16.08.00_0x06060A05
|
||
|
Preboot CLI Version = 04.04-020:#%00009
|
||
|
WebBIOS Version = 6.0-54-e_50-Rel
|
||
|
NVDATA Version = 2.09.03-0058
|
||
|
Boot Block Version = 2.02.00.00-0000
|
||
|
Bootloader Version = 09.250.01.219
|
||
|
Driver Name = megaraid_sas
|
||
|
Driver Version = 07.717.02.00-rc1
|
||
|
|
||
|
|
||
|
Bus :
|
||
|
===
|
||
|
Vendor Id = 0x1000
|
||
|
Device Id = 0x79
|
||
|
SubVendor Id = 0x15D9
|
||
|
SubDevice Id = 0x700
|
||
|
Host Interface = PCI-E
|
||
|
Device Interface = SAS-6G
|
||
|
Bus Number = 130
|
||
|
Device Number = 0
|
||
|
Function Number = 0
|
||
|
|
||
|
|
||
|
Pending Images in Flash :
|
||
|
=======================
|
||
|
Image name = No pending images
|
||
|
|
||
|
|
||
|
Status :
|
||
|
======
|
||
|
Controller Status = Optimal
|
||
|
Memory Correctable Errors = 0
|
||
|
Memory Uncorrectable Errors = 0
|
||
|
ECC Bucket Count = 0
|
||
|
Any Offline VD Cache Preserved = No
|
||
|
BBU Status = 44
|
||
|
Support PD Firmware Download = No
|
||
|
Lock Key Assigned = No
|
||
|
Failed to get lock key on bootup = No
|
||
|
Lock key has not been backed up = No
|
||
|
Bios was not detected during boot = No
|
||
|
Controller must be rebooted to complete security operation = No
|
||
|
A rollback operation is in progress = No
|
||
|
At least one PFK exists in NVRAM = No
|
||
|
SSC Policy is WB = No
|
||
|
Controller has booted into safe mode = No
|
||
|
|
||
|
|
||
|
Supported Adapter Operations :
|
||
|
============================
|
||
|
Rebuild Rate = Yes
|
||
|
CC Rate = Yes
|
||
|
BGI Rate = Yes
|
||
|
Reconstruct Rate = Yes
|
||
|
Patrol Read Rate = Yes
|
||
|
Alarm Control = Yes
|
||
|
Cluster Support = No
|
||
|
BBU = Yes
|
||
|
Spanning = Yes
|
||
|
Dedicated Hot Spare = Yes
|
||
|
Revertible Hot Spares = Yes
|
||
|
Foreign Config Import = Yes
|
||
|
Self Diagnostic = Yes
|
||
|
Allow Mixed Redundancy on Array = No
|
||
|
Global Hot Spares = Yes
|
||
|
Deny SCSI Passthrough = No
|
||
|
Deny SMP Passthrough = No
|
||
|
Deny STP Passthrough = No
|
||
|
Support more than 8 Phys = Yes
|
||
|
FW and Event Time in GMT = No
|
||
|
Support Enhanced Foreign Import = Yes
|
||
|
Support Enclosure Enumeration = Yes
|
||
|
Support Allowed Operations = Yes
|
||
|
Abort CC on Error = Yes
|
||
|
Support Multipath = Yes
|
||
|
Support Odd & Even Drive count in RAID1E = No
|
||
|
Support Security = No
|
||
|
Support Config Page Model = Yes
|
||
|
Support the OCE without adding drives = Yes
|
||
|
Support EKM = No
|
||
|
Snapshot Enabled = No
|
||
|
Support PFK = Yes
|
||
|
Support PI = No
|
||
|
Support Ld BBM Info = No
|
||
|
Support Shield State = No
|
||
|
Block SSD Write Disk Cache Change = No
|
||
|
Support Suspend Resume BG ops = No
|
||
|
Support Emergency Spares = Yes
|
||
|
Support Set Link Speed = No
|
||
|
Support Boot Time PFK Change = No
|
||
|
Support JBOD = No
|
||
|
Disable Online PFK Change = No
|
||
|
Support Perf Tuning = No
|
||
|
Support SSD PatrolRead = Yes
|
||
|
Real Time Scheduler = Yes
|
||
|
Support Reset Now = Yes
|
||
|
Support Emulated Drives = Yes
|
||
|
Headless Mode = Yes
|
||
|
Dedicated HotSpares Limited = No
|
||
|
Point In Time Progress = No
|
||
|
Extended LD = No
|
||
|
Boot Volume Supported = No
|
||
|
Support Uneven span = No
|
||
|
Support Config Auto Balance = No
|
||
|
Support Maintenance Mode = No
|
||
|
Support Diagnostic results = No
|
||
|
Support Ext Enclosure = No
|
||
|
Support Sesmonitoring = No
|
||
|
Support SecurityonJBOD = No
|
||
|
Support ForceFlash = No
|
||
|
Support DisableImmediateIO = Yes
|
||
|
Support LargeIOSupport = No
|
||
|
Support DrvActivityLEDSetting = Yes
|
||
|
Support FlushWriteVerify = No
|
||
|
Support CPLDUpdate = No
|
||
|
Support ForceTo512e = No
|
||
|
Support discardCacheDuringLDDelete = No
|
||
|
Support JBOD Write cache = No
|
||
|
Support Large QD Support = No
|
||
|
Support SRIOV Options = No
|
||
|
|
||
|
|
||
|
Supported PD Operations :
|
||
|
=======================
|
||
|
Force Online = Yes
|
||
|
Force Offline = Yes
|
||
|
Force Rebuild = Yes
|
||
|
Deny Force Failed = No
|
||
|
Deny Force Good/Bad = No
|
||
|
Deny Missing Replace = No
|
||
|
Deny Clear = No
|
||
|
Deny Locate = No
|
||
|
Support Power State = Yes
|
||
|
Set Power State For Cfg = No
|
||
|
Support T10 Power State = No
|
||
|
Support Temperature = Yes
|
||
|
NCQ = No
|
||
|
Support Max Rate SATA = No
|
||
|
Support Degraded Media = No
|
||
|
Support Parallel FW Update = No
|
||
|
Support Drive Crypto Erase = No
|
||
|
|
||
|
|
||
|
Supported VD Operations :
|
||
|
=======================
|
||
|
Read Policy = Yes
|
||
|
Write Policy = Yes
|
||
|
IO Policy = Yes
|
||
|
Access Policy = Yes
|
||
|
Disk Cache Policy = Yes
|
||
|
Reconstruction = Yes
|
||
|
Deny Locate = No
|
||
|
Deny CC = No
|
||
|
Allow Ctrl Encryption = No
|
||
|
Enable LDBBM = Yes
|
||
|
Support FastPath = No
|
||
|
Performance Metrics = Yes
|
||
|
Power Savings = No
|
||
|
Support Powersave Max With Cache = No
|
||
|
Support Breakmirror = No
|
||
|
Support SSC WriteBack = No
|
||
|
Support SSC Association = Yes
|
||
|
Support VD Hide = No
|
||
|
Support VD Cachebypass = No
|
||
|
Support VD discardCacheDuringLDDelete = No
|
||
|
|
||
|
|
||
|
Advanced Software Option :
|
||
|
========================
|
||
|
|
||
|
-------------------------------------
|
||
|
Adv S/W Opt Time Remaining Mode
|
||
|
-------------------------------------
|
||
|
MegaRAID RAID6 Unlimited -
|
||
|
MegaRAID RAID5 Unlimited -
|
||
|
-------------------------------------
|
||
|
|
||
|
Safe ID = JJ17M5BUPUQ81RDKM9HGF7IMB81U6ME2RUI7432Z
|
||
|
|
||
|
HwCfg :
|
||
|
=====
|
||
|
ChipRevision = B4
|
||
|
BatteryFRU = N/A
|
||
|
Front End Port Count = 0
|
||
|
Backend Port Count = 8
|
||
|
BBU = Present
|
||
|
Alarm = On
|
||
|
Serial Debugger = Present
|
||
|
NVRAM Size = 32KB
|
||
|
Flash Size = 8MB
|
||
|
On Board Memory Size = 512MB
|
||
|
CacheVault Flash Size = NA
|
||
|
TPM = Absent
|
||
|
Upgrade Key = Absent
|
||
|
On Board Expander = Absent
|
||
|
Temperature Sensor for ROC = Absent
|
||
|
Temperature Sensor for Controller = Absent
|
||
|
Upgradable CPLD = Absent
|
||
|
Current Size of CacheCade (GB) = 0
|
||
|
Current Size of FW Cache (MB) = 346
|
||
|
|
||
|
|
||
|
Policies :
|
||
|
========
|
||
|
|
||
|
Policies Table :
|
||
|
==============
|
||
|
|
||
|
------------------------------------------------
|
||
|
Policy Current Default
|
||
|
------------------------------------------------
|
||
|
Predictive Fail Poll Interval 300 sec
|
||
|
Interrupt Throttle Active Count 16
|
||
|
Interrupt Throttle Completion 50 us
|
||
|
Rebuild Rate 30 % 30%
|
||
|
PR Rate 30 % 30%
|
||
|
BGI Rate 30 % 30%
|
||
|
Check Consistency Rate 30 % 30%
|
||
|
Reconstruction Rate 30 % 30%
|
||
|
Cache Flush Interval 4s
|
||
|
------------------------------------------------
|
||
|
|
||
|
Flush Time(Default) = 4s
|
||
|
Drive Coercion Mode = 1GB
|
||
|
Auto Rebuild = On
|
||
|
Battery Warning = On
|
||
|
ECC Bucket Size = 15
|
||
|
ECC Bucket Leak Rate (hrs) = 24
|
||
|
Restore HotSpare on Insertion = Off
|
||
|
Expose Enclosure Devices = On
|
||
|
Maintain PD Fail History = Off
|
||
|
Reorder Host Requests = On
|
||
|
Auto detect BackPlane = SGPIO/i2c SEP
|
||
|
Load Balance Mode = Auto
|
||
|
Security Key Assigned = Off
|
||
|
Disable Online Controller Reset = Off
|
||
|
Use drive activity for locate = Off
|
||
|
|
||
|
|
||
|
Boot :
|
||
|
====
|
||
|
BIOS Enumerate VDs = 1
|
||
|
Stop BIOS on Error = On
|
||
|
Delay during POST = 0
|
||
|
Spin Down Mode = None
|
||
|
Enable Ctrl-R = No
|
||
|
Enable Web BIOS = Yes
|
||
|
Enable PreBoot CLI = Yes
|
||
|
Enable BIOS = Yes
|
||
|
Max Drives to Spinup at One Time = 4
|
||
|
Maximum number of direct attached drives to spin up in 1 min = 120
|
||
|
Delay Among Spinup Groups (sec) = 2
|
||
|
Allow Boot with Preserved Cache = Off
|
||
|
|
||
|
|
||
|
High Availability :
|
||
|
=================
|
||
|
Topology Type = None
|
||
|
Cluster Permitted = No
|
||
|
Cluster Active = No
|
||
|
|
||
|
|
||
|
Defaults :
|
||
|
========
|
||
|
Phy Polarity = 0
|
||
|
Phy PolaritySplit = 0
|
||
|
Strip Size = 64 KB
|
||
|
Write Policy = WB
|
||
|
Read Policy = Adaptive
|
||
|
Cache When BBU Bad = On
|
||
|
Cached IO = On
|
||
|
VD PowerSave Policy = Controller Defined
|
||
|
Default spin down time (mins) = 30
|
||
|
Coercion Mode = 1 GB
|
||
|
ZCR Config = Unknown
|
||
|
Max Chained Enclosures = 16
|
||
|
Direct PD Mapping = Yes
|
||
|
Restore Hot Spare on Insertion = No
|
||
|
Expose Enclosure Devices = Yes
|
||
|
Maintain PD Fail History = No
|
||
|
Zero Based Enclosure Enumeration = No
|
||
|
Disable Puncturing = No
|
||
|
EnableLDBBM = Yes
|
||
|
DisableHII = No
|
||
|
Un-Certified Hard Disk Drives = Allow
|
||
|
SMART Mode = Mode 6
|
||
|
Enable LED Header = No
|
||
|
LED Show Drive Activity = Yes
|
||
|
Dirty LED Shows Drive Activity = No
|
||
|
EnableCrashDump = No
|
||
|
Disable Online Controller Reset = No
|
||
|
Treat Single span R1E as R10 = No
|
||
|
Power Saving option = Enabled
|
||
|
TTY Log In Flash = No
|
||
|
Auto Enhanced Import = No
|
||
|
BreakMirror RAID Support = No
|
||
|
Disable Join Mirror = No
|
||
|
Enable Shield State = No
|
||
|
Time taken to detect CME = 60 sec
|
||
|
|
||
|
|
||
|
Capabilities :
|
||
|
============
|
||
|
Supported Drives = SAS, SATA
|
||
|
Boot Volume Supported = NO
|
||
|
RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50,
|
||
|
RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported,
|
||
|
PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
|
||
|
Enable JBOD = No
|
||
|
Mix in Enclosure = Allowed
|
||
|
Mix of SAS/SATA of HDD type in VD = Allowed
|
||
|
Mix of SAS/SATA of SSD type in VD = Allowed
|
||
|
Mix of SSD/HDD in VD = Allowed
|
||
|
SAS Disable = No
|
||
|
Max Arms Per VD = 32
|
||
|
Max Spans Per VD = 8
|
||
|
Max Arrays = 128
|
||
|
Max VD per array = 16
|
||
|
Max Number of VDs = 64
|
||
|
Max Parallel Commands = 1008
|
||
|
Max SGE Count = 80
|
||
|
Max Data Transfer Size = 8192 sectors
|
||
|
Max Strips PerIO = 42
|
||
|
Max Configurable CacheCade Size(GB) = 0
|
||
|
Max Transportable DGs = 0
|
||
|
Min Strip Size = 8 KB
|
||
|
Max Strip Size = 1.0 MB
|
||
|
|
||
|
|
||
|
Scheduled Tasks :
|
||
|
===============
|
||
|
Consistency Check Reoccurrence = 672 hrs
|
||
|
Next Consistency check launch = 12/24/2022, 04:00:00
|
||
|
Patrol Read Reoccurrence = 672 hrs
|
||
|
Next Patrol Read launch = 12/25/2022, 04:00:00
|
||
|
Battery learn Reoccurrence = 672 hrs
|
||
|
Next Battery Learn = 12/24/2022, 04:00:00
|
||
|
OEMID = LSI
|
||
|
|
||
|
Drive Groups = 1
|
||
|
|
||
|
TOPOLOGY :
|
||
|
========
|
||
|
|
||
|
----------------------------------------------------------------------------
|
||
|
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
|
||
|
----------------------------------------------------------------------------
|
||
|
0 - - - - RAID5 Optl Y 10.913 TB dflt N N none N N
|
||
|
0 0 - - - RAID5 Optl Y 10.913 TB dflt N N none N N
|
||
|
0 0 0 252:0 0 DRIVE Onln N 2.727 TB dflt N N none - N
|
||
|
0 0 1 252:1 1 DRIVE Onln N 2.727 TB dflt N N none - N
|
||
|
0 0 2 252:2 2 DRIVE Onln N 2.727 TB dflt N N none - N
|
||
|
0 0 3 252:3 3 DRIVE Onln N 2.727 TB dflt N N none - N
|
||
|
0 0 4 252:4 4 DRIVE Onln N 2.727 TB dflt N N none - N
|
||
|
----------------------------------------------------------------------------
|
||
|
|
||
|
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
|
||
|
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
|
||
|
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
|
||
|
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
|
||
|
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
|
||
|
TR=Transport Ready
|
||
|
|
||
|
Virtual Drives = 1
|
||
|
|
||
|
VD LIST :
|
||
|
=======
|
||
|
|
||
|
--------------------------------------------------------------
|
||
|
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
|
||
|
--------------------------------------------------------------
|
||
|
0/0 RAID5 Optl RW Yes RWBC - ON 10.913 TB
|
||
|
--------------------------------------------------------------
|
||
|
|
||
|
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
|
||
|
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
|
||
|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
|
||
|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
|
||
|
Check Consistency
|
||
|
|
||
|
Physical Drives = 5
|
||
|
|
||
|
PD LIST :
|
||
|
=======
|
||
|
|
||
|
-----------------------------------------------------------------------------------
|
||
|
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
|
||
|
-----------------------------------------------------------------------------------
|
||
|
252:0 0 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:1 1 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:2 2 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:3 3 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:4 4 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
-----------------------------------------------------------------------------------
|
||
|
|
||
|
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
|
||
|
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
|
||
|
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
|
||
|
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
|
||
|
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
|
||
|
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
|
||
|
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
|
||
|
|
||
|
|
||
|
BBU_Info :
|
||
|
========
|
||
|
|
||
|
-----------------------------------------------------------------------
|
||
|
Model State RetentionTime Temp Mode MfgDate Next Learn
|
||
|
-----------------------------------------------------------------------
|
||
|
iBBU08 Optimal 48 hours + 47C 1 2012/08/22 2022/13/24 04:00:00
|
||
|
-----------------------------------------------------------------------
|
||
|
|
||
|
Mode 1: 12+ Hrs retention with a transparent learn cycle
|
||
|
and best service life.
|
||
|
|
||
|
Controller = 0
|
||
|
Status = Success
|
||
|
Description = None
|
||
|
|
||
|
|
||
|
/c0/v0 :
|
||
|
======
|
||
|
|
||
|
--------------------------------------------------------------
|
||
|
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
|
||
|
--------------------------------------------------------------
|
||
|
0/0 RAID5 Optl RW Yes RWBC - ON 10.913 TB
|
||
|
--------------------------------------------------------------
|
||
|
|
||
|
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
|
||
|
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
|
||
|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
|
||
|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
|
||
|
Check Consistency
|
||
|
|
||
|
|
||
|
PDs for VD 0 :
|
||
|
============
|
||
|
|
||
|
-----------------------------------------------------------------------------------
|
||
|
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
|
||
|
-----------------------------------------------------------------------------------
|
||
|
252:0 0 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:1 1 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:2 2 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:3 3 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
252:4 4 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
|
||
|
-----------------------------------------------------------------------------------
|
||
|
|
||
|
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
|
||
|
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
|
||
|
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
|
||
|
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
|
||
|
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
|
||
|
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
|
||
|
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
|
||
|
|
||
|
|
||
|
VD0 Properties :
|
||
|
==============
|
||
|
Strip Size = 64 KB
|
||
|
Number of Blocks = 23437492224
|
||
|
VD has Emulated PD = No
|
||
|
Span Depth = 1
|
||
|
Number of Drives Per Span = 5
|
||
|
Write Cache(initial setting) = WriteBack
|
||
|
Disk Cache Policy = Disk's Default
|
||
|
Encryption = None
|
||
|
Data Protection = None
|
||
|
Active Operations = Consistency Check (95%)
|
||
|
Exposed to OS = Yes
|
||
|
Creation Date = 29-04-2021
|
||
|
Creation Time = 10:53:28 AM
|
||
|
Emulation type = default
|
||
|
Is LD Ready for OS Requests = Yes
|
||
|
SCSI NAA Id = 6003048014579200281d4ca843bb0950
|
||
|
|
||
|
|