Generating detailed summary of the adapter, it may take a while to complete. CLI Version = 007.0529.0000.0000 Sep 18, 2018 Operating system = Linux 4.9.0-18-amd64 Controller = 0 Status = Success Description = None Basics : ====== Controller = 0 Model = PERC H730P Adapter Serial Number = 8BN01234 Current Controller Date/Time = 06/27/2022, 21:30:40 Current System Date/time = 06/27/2022, 23:30:42 SAS Address = 54cdabf010303400 PCI Address = 00:18:00:00 Mfg Date = 11/27/18 Rework Date = 11/27/18 Revision No = A04 Version : ======= Firmware Package Build = 25.5.5.0005 Firmware Version = 4.290.00-8334 Bios Version = 6.33.01.0_4.16.07.00_0x06120304 Ctrl-R Version = 5.18-0701 NVDATA Version = 3.1511.00-0028 Boot Block Version = 3.07.00.00-0003 Driver Name = megaraid_sas Driver Version = 07.700.00.00-rc1 Bus : === Vendor Id = 0x1000 Device Id = 0x5D SubVendor Id = 0x1028 SubDevice Id = 0x1F42 Host Interface = PCI-E Device Interface = SAS-12G Bus Number = 24 Device Number = 0 Function Number = 0 Pending Images in Flash : ======================= Image name = No pending images Status : ====== Controller Status = Optimal Memory Correctable Errors = 0 Memory Uncorrectable Errors = 0 ECC Bucket Count = 0 Any Offline VD Cache Preserved = No BBU Status = 0 PD Firmware Download in progress = No Lock Key Assigned = No Failed to get lock key on bootup = No Lock key has not been backed up = No Bios was not detected during boot = No Controller must be rebooted to complete security operation = No A rollback operation is in progress = No At least one PFK exists in NVRAM = No SSC Policy is WB = No Controller has booted into safe mode = No Current Personality = RAID-Mode Supported Adapter Operations : ============================ Rebuild Rate = Yes CC Rate = Yes BGI Rate = Yes Reconstruct Rate = Yes Patrol Read Rate = Yes Alarm Control = Yes Cluster Support = No BBU = Yes Spanning = Yes Dedicated Hot Spare = Yes Revertible Hot Spares = Yes Foreign Config Import = Yes Self Diagnostic = Yes Allow Mixed Redundancy on Array = No Global Hot Spares = Yes Deny SCSI Passthrough = No Deny SMP Passthrough = No Deny STP Passthrough = No Support more than 8 Phys = Yes FW and Event Time in GMT = No Support Enhanced Foreign Import = Yes Support Enclosure Enumeration = Yes Support Allowed Operations = Yes Abort CC on Error = Yes Support Multipath = Yes Support Odd & Even Drive count in RAID1E = No Support Security = Yes Support Config Page Model = Yes Support the OCE without adding drives = Yes Support EKM = No Snapshot Enabled = No Support PFK = No Support PI = No Support Ld BBM Info = No Support Shield State = Yes Block SSD Write Disk Cache Change = No Support Suspend Resume BG ops = Yes Support Emergency Spares = No Support Set Link Speed = Yes Support Boot Time PFK Change = No Support SystemPD = Yes Disable Online PFK Change = No Support Perf Tuning = Yes Support SSD PatrolRead = Yes Real Time Scheduler = No Support Reset Now = Yes Support Emulated Drives = Yes Headless Mode = Yes Dedicated HotSpares Limited = No Point In Time Progress = No Extended LD = Yes Boot Volume Supported = No Support Uneven span = Yes Support Config Auto Balance = No Support Maintenance Mode = No Support Diagnostic results = Yes Support Ext Enclosure = No Support Sesmonitoring = No Support SecurityonJBOD = No Support ForceFlash = No Support DisableImmediateIO = No Support LargeIOSupport = Yes Support DrvActivityLEDSetting = No Support FlushWriteVerify = No Support CPLDUpdate = No Support ForceTo512e = No Support discardCacheDuringLDDelete = No Support JBOD Write cache = Yes Support Large QD Support = No Support Ctrl Info Extended = No Support IButton less = No Support AES Encryption Algorithm = No Support Encrypted MFC = No Support Force Personality Change = No Enterprise Key management : ========================= Capability = Not Supported Supported PD Operations : ======================= Force Online = Yes Force Offline = Yes Force Rebuild = Yes Deny Force Failed = No Deny Force Good/Bad = No Deny Missing Replace = No Deny Clear = No Deny Locate = No Support Power State = Yes Set Power State For Cfg = No Support T10 Power State = Yes Support Temperature = Yes NCQ = No Support Max Rate SATA = No Support Degraded Media = No Support Parallel FW Update = No Support Drive Crypto Erase = Yes Supported VD Operations : ======================= Read Policy = Yes Write Policy = Yes IO Policy = Yes Access Policy = Yes Disk Cache Policy = Yes Reconstruction = Yes Deny Locate = No Deny CC = No Allow Ctrl Encryption = No Enable LDBBM = Yes Support FastPath = Yes Performance Metrics = Yes Power Savings = Yes Support Powersave Max With Cache = No Support Breakmirror = Yes Support SSC WriteBack = No Support SSC Association = No Support VD Hide = No Support VD Cachebypass = Yes Support VD discardCacheDuringLDDelete = No Support VD Scsi Unmap = No HwCfg : ===== ChipRevision = C0 BatteryFRU = N/A Front End Port Count = 0 Backend Port Count = 8 BBU = Present Alarm = Missing Serial Debugger = Present NVRAM Size = 32KB Flash Size = 16MB On Board Memory Size = 2048MB CacheVault Flash Size = 4.0 GB TPM = Absent Upgrade Key = Absent On Board Expander = Absent Temperature Sensor for ROC = Present Temperature Sensor for Controller = Present Upgradable CPLD = Absent Current Size of CacheCade (GB) = 0 Current Size of FW Cache (MB) = 1931 ROC temperature(Degree Celsius) = 56 Ctrl temperature(Degree Celsius) = 56 Policies : ======== Policies Table : ============== ------------------------------------------------ Policy Current Default ------------------------------------------------ Predictive Fail Poll Interval 300 sec Interrupt Throttle Active Count 16 Interrupt Throttle Completion 50 us Rebuild Rate 30 % 30% PR Rate 30 % 30% BGI Rate 30 % 30% Check Consistency Rate 30 % 30% Reconstruction Rate 30 % 30% Cache Flush Interval 4s ------------------------------------------------ Flush Time(Default) = 4s Drive Coercion Mode = 128MB Auto Rebuild = On Battery Warning = On ECC Bucket Size = 255 ECC Bucket Leak Rate (hrs) = 4 Restore HotSpare on Insertion = Off Expose Enclosure Devices = Off Maintain PD Fail History = Off Reorder Host Requests = On Auto detect BackPlane = SGPIO/i2c SEP Load Balance Mode = Auto Security Key Assigned = Off Disable Online Controller Reset = Off Use drive activity for locate = Off Boot : ==== BIOS Enumerate VDs = 1 Stop BIOS on Error = Off Delay during POST = 0 Spin Down Mode = None Enable Ctrl-R = Yes Enable Web BIOS = No Enable PreBoot CLI = No Enable BIOS = Yes Max Drives to Spinup at One Time = 4 Maximum number of direct attached drives to spin up in 1 min = 0 Delay Among Spinup Groups (sec) = 12 Allow Boot with Preserved Cache = Off High Availability : ================= Topology Type = None Cluster Permitted = No Cluster Active = No Defaults : ======== Phy Polarity = 0 Phy PolaritySplit = 0 Strip Size = 64 KB Write Policy = WB Read Policy = Adaptive Cache When BBU Bad = Off Cached IO = Off VD PowerSave Policy = Controller Defined Default spin down time (mins) = 30 Coercion Mode = 128 MB ZCR Config = Unknown Max Chained Enclosures = 4 Direct PD Mapping = Yes Restore Hot Spare on Insertion = No Expose Enclosure Devices = No Maintain PD Fail History = No Zero Based Enclosure Enumeration = Yes Disable Puncturing = No EnableLDBBM = Yes DisableHII = No Un-Certified Hard Disk Drives = Allow SMART Mode = Mode 6 Enable LED Header = No LED Show Drive Activity = Yes Dirty LED Shows Drive Activity = No EnableCrashDump = No Disable Online Controller Reset = No Treat Single span R1E as R10 = Yes Power Saving option = Enabled TTY Log In Flash = Yes Auto Enhanced Import = No BreakMirror RAID Support = Yes Disable Join Mirror = Yes Enable Shield State = No Time taken to detect CME = 60 sec Capabilities : ============ Supported Drives = SAS, SATA Boot Volume Supported = NO RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID10(2 or more drives per span), RAID50, RAID60 Enable SystemPD = Yes Mix in Enclosure = Allowed Mix of SAS/SATA of HDD type in VD = Not Allowed Mix of SAS/SATA of SSD type in VD = Not Allowed Mix of SSD/HDD in VD = Not Allowed SAS Disable = No Max Arms Per VD = 32 Max Spans Per VD = 8 Max Arrays = 128 Max VD per array = 16 Max Number of VDs = 64 Max Parallel Commands = 928 Max SGE Count = 60 Max Data Transfer Size = 8192 sectors Max Strips PerIO = 128 Max Configurable CacheCade Size(GB) = 0 Max Transportable DGs = 0 Min Strip Size = 64 KB Max Strip Size = 1.0 MB Scheduled Tasks : =============== Consistency Check Reoccurrence = 168 hrs Next Consistency check launch = NA Patrol Read Reoccurrence = 168 hrs Next Patrol Read launch = 07/02/2022, 03:00:00 Battery learn Reoccurrence = 2160 hrs OEMID = Dell Drive Groups = 2 TOPOLOGY : ======== ----------------------------------------------------------------------------- DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR ----------------------------------------------------------------------------- 0 - - - - RAID1 Optl N 744.625 GB dflt N N dflt N N 0 0 - - - RAID1 Optl N 744.625 GB dflt N N dflt N N 0 0 0 32:0 0 DRIVE Onln N 744.625 GB dflt N N dflt - N 0 0 1 32:1 1 DRIVE Onln N 744.625 GB dflt N N dflt - N 1 - - - - RAID5 Optl N 2.727 TB dflt N N dflt N N 1 0 - - - RAID5 Optl N 2.727 TB dflt N N dflt N N 1 0 0 32:2 2 DRIVE Onln N 931.0 GB dflt N N dflt - N 1 0 1 32:3 3 DRIVE Onln N 931.0 GB dflt N N dflt - N 1 0 2 32:4 4 DRIVE Onln N 931.0 GB dflt N N dflt - N 1 0 3 32:5 5 DRIVE Onln N 931.0 GB dflt N N dflt - N ----------------------------------------------------------------------------- DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present TR=Transport Ready Virtual Drives = 2 VD LIST : ======= ------------------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name ------------------------------------------------------------------------- 0/0 RAID1 Optl RW Yes RWBD - OFF 744.625 GB Virtual Disk 0 1/1 RAID5 Optl RW Yes RWBD - OFF 2.727 TB Virtual Disk 1 ------------------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency Physical Drives = 6 PD LIST : ======= --------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type --------------------------------------------------------------------------- 32:0 0 Onln 0 744.625 GB SATA SSD N N 512B SSDSC2BB800G7 U - 32:1 1 Onln 0 744.625 GB SATA SSD N N 512B SSDSC2BB800G7 U - 32:2 2 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - 32:3 3 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - 32:4 4 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - 32:5 5 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - --------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encrypting Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded BBU_Info : ======== ---------------------------------------------- Model State RetentionTime Temp Mode MfgDate ---------------------------------------------- BBU Optimal 0 hour(s) 25C - 0/00/00 ---------------------------------------------- CLI Version = 007.0529.0000.0000 Sep 18, 2018 Operating system = Linux 4.9.0-18-amd64 Controller = 0 Status = Success Description = None /c0/v0 : ====== ------------------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name ------------------------------------------------------------------------- 0/0 RAID1 Optl RW Yes RWBD - OFF 744.625 GB Virtual Disk 0 ------------------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency PDs for VD 0 : ============ --------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type --------------------------------------------------------------------------- 32:0 0 Onln 0 744.625 GB SATA SSD N N 512B THNSF8800CCSE U - 32:1 1 Onln 0 744.625 GB SATA SSD N N 512B THNSF8800CCSE U - --------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encrypting Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded VD0 Properties : ============== Strip Size = 64 KB Number of Blocks = 1561591808 VD has Emulated PD = No Span Depth = 1 Number of Drives Per Span = 2 Write Cache(initial setting) = WriteBack Disk Cache Policy = Disk's Default Encryption = None Data Protection = None Active Operations = None Exposed to OS = Yes Creation Date = 04-01-2019 Creation Time = 11:04:16 PM Emulation type = default Cachebypass size = Cachebypass-64k Cachebypass Mode = Cachebypass Intelligent Is LD Ready for OS Requests = Yes SCSI NAA Id = 64cd98f040f0fd0023c2a2f070eefd16 SCSI Unmap = No /c0/v1 : ====== ----------------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name ----------------------------------------------------------------------- 1/1 RAID5 Optl RW Yes RWBD - OFF 2.727 TB Virtual Disk 1 ----------------------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency PDs for VD 1 : ============ ------------------------------------------------------------------------ EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ------------------------------------------------------------------------ 32:2 2 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - 32:3 3 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - 32:4 4 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - 32:5 5 Onln 1 931.0 GB SATA HDD N N 512B ST1000NX0443 U - ------------------------------------------------------------------------ EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encrypting Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down/PowerSave|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded VD1 Properties : ============== Strip Size = 64 KB Number of Blocks = 5857345536 VD has Emulated PD = No Span Depth = 1 Number of Drives Per Span = 4 Write Cache(initial setting) = WriteBack Disk Cache Policy = Disk's Default Encryption = None Data Protection = None Active Operations = None Exposed to OS = Yes Creation Date = 04-01-2019 Creation Time = 11:04:44 PM Emulation type = default Cachebypass size = Cachebypass-64k Cachebypass Mode = Cachebypass Intelligent Is LD Ready for OS Requests = Yes SCSI NAA Id = 64cd98f040f0fd0023c2a30c729a1fb9 SCSI Unmap = No