Generating detailed summary of the adapter, it may take a while to complete. Controller = 0 Status = Success Description = None Basics : ====== Controller = 0 Model = ServeRAID M5210 Serial Number = SV54341012 Current Controller Date/Time = 09/23/2016, 15:04:05 Current System Date/time = 09/23/2016, 15:04:05 SAS Address = 500605b00b3ee5e0 PCI Address = 00:01:00:00 Mfg Date = 10/28/15 Rework Date = 00/00/00 Revision No = 04D Version : ======= Firmware Package Build = 24.12.0-0024 Firmware Version = 4.620.00-6070 BIOS Version = 6.30.03.0_4.17.08.00_0x06130200 NVDATA Version = 3.1511.00-0009 Ctrl-R Version = 5.15-1002 Preboot CLI Version = 01.07-05:#%0000 Boot Block Version = 3.07.00.00-0003 Driver Name = megasas2.sys Driver Version = 6.710.15.00 Bus : === Vendor ID = 0x1000 Device ID = 0x5D SubVendor ID = 0x1014 SubDevice ID = 0x454 Host Interface = PCIE Device Interface = SAS-12G Bus Number = 1 Device Number = 0 Function Number = 0 Pending Images in Flash : ======================= Image name = No pending images Status : ====== Controller Status = Optimal Memory Correctable Errors = 0 Memory Uncorrectable Errors = 0 ECC Bucket Count = 0 Any Offline VD Cache Preserved = No BBU Status = 0 Support PD Firmware Download = No Lock Key Assigned = No Failed to get lock key on bootup = No Lock key has not been backed up = No BIOS was not detected during boot = No Controller must be rebooted to complete security operation = No A rollback operation is in progress = No At least one PFK exists in NVRAM = No SSC Policy is WB = No Controller has booted into safe mode = No Supported Adapter Operations : ============================ Rebuild Rate = Yes CC Rate = Yes BGI Rate = Yes Reconstruct Rate = Yes Patrol Read Rate = Yes Alarm Control = No Cluster Support = No BBU = Yes Spanning = Yes Dedicated Hot Spare = Yes Revertible Hot Spares = Yes Foreign Config Import = Yes Self Diagnostic = Yes Allow Mixed Redundancy on Array = No Global Hot Spares = Yes Deny SCSI Passthrough = No Deny SMP Passthrough = No Deny STP Passthrough = No Support more than 8 Phys = Yes firmware and Event Time in GMT = No Support Enhanced Foreign Import = Yes Support Enclosure Enumeration = Yes Support Allowed Operations = Yes Abort CC on Error = Yes Support Multipath = Yes Support Odd and Even Drive count in RAID1E = No Support Security = Yes Support Config Page Model = Yes Support the OCE without adding drives = Yes support EKM = Yes Snapshot Enabled = No Support PFK = Yes Support PI = Yes Support LDPI Type1 = No Support LDPI Type2 = No Support LDPI Type3 = No Support Ld BBM Info = No Support Shield State = Yes Block SSD Write Disk Cache Change = Yes Support Suspend Resume BG ops = Yes Support Emergency Spares = Yes Support Set Link Speed = Yes Support Boot Time PFK Change = Yes Support JBOD = Yes Disable Online PFK Change = Yes Support Perf Tuning = Yes Support SSD PatrolRead = Yes Real Time Scheduler = Yes Support Reset Now = Yes Support Emulated Drives = Yes Headless Mode = Yes Dedicated HotSpares Limited = No Point In Time Progress = Yes Extended LD = Yes Supported PD Operations : ======================= Force Online = Yes Force Offline = Yes Force Rebuild = Yes Deny Force Failed = No Deny Force Good/Bad = No Deny Missing Replace = No Deny Clear = No Deny Locate = No Support Power State = No Set Power State For Cfg = No Support T10 Power State = No Support Temperature = Yes NCQ = Yes Supported VD Operations : ======================= Read Policy = Yes Write Policy = Yes I/O Policy = Yes Access Policy = Yes Disk Cache Policy = Yes Reconstruction = Yes Deny Locate = No Deny CC = No Allow Ctrl Encryption = No Enable LDBBM = No Support FastPath = No Performance Metrics = Yes Power Savings = No Support Powersave Max With Cache = No Support Breakmirror = Yes Support SSC WriteBack = No Support SSC Association = No Advanced Software Option part number : ======================== -------------------------------------------- Adv S/W Opt Time Remaining Mode -------------------------------------------- MegaRAID SafeStore Unlimited Secured MegaRAID RAID5 Unlimited Secured -------------------------------------------- Safe ID = XCR9FXJX6PQ866ND56BJ86DU5V7CQ8XG4NQAKDRZ HwCfg : ===== ChipRevision = C0 BatteryFRU = N/A Front End Port Count = 0 Backend Port Count = 8 BBU = Present Alarm = Missing Serial Debugger = Present NVRAM Size = 32KB Flash Size = 32MB On Board Memory Size = 1024MB On Board Expander = Absent Temperature Sensor for ROC = Present Temperature Sensor for Controller = Absent Current Size of CacheCade (GB) = 0 Current Size of firmware Cache (MB) = 651 ROC temperature(Degree Celcius) = 72 Policies : ======== Policies Table : ============== ------------------------------------------------ Policy Current Default ------------------------------------------------ Predictive Fail Poll Interval 300 sec Interrupt Throttle Active Count 16 Interrupt Throttle Completion 50 us Rebuild Rate 30 % 30% PR Rate 30 % 30% BGI Rate 30 % 30% Check Consistency Rate 30 % 30% Reconstruction Rate 30 % 30% Cache Flush Interval 0s ------------------------------------------------ Flush Time(Default) = 4s Drive Coercion Mode = 1GB Auto Rebuild = On Battery Warning = On ECC Bucket Size = 15 ECC Bucket Leak Rate (hrs) = 24 Restore HotSpare on Insertion = Off Expose Enclosure Devices = On Maintain PD Fail History = On Reorder Host Requests = On Auto detect BackPlane = SGPIO/i2c SEP Load Balance Mode = Auto Security Key Assigned = Off Disable Online Controller Reset = Off Use drive activity for locate = Off Boot : ==== BIOS Enumerate VDs = 1 Stop BIOS on Error = On Delay during POST = 0 Spin Down Mode = None Enable Ctrl-R = No Enable Web BIOS = No Enable PreBoot CLI = No Enable BIOS = Yes Max Drives to Spinup at One Time = 2 Maximum number of direct attached drives to spin up in 1 min = 10 Delay Among Spinup Groups (sec) = 12 Allow Boot with Preserved Cache = Off High Availability : ================= Topology Type = None Cluster Permitted = No Cluster Active = No Defaults : ======== Phy Polarity = 0 Phy PolaritySplit = 0 Strip Size = 256kB Write Policy = WB Read Policy = Adaptive Cache When BBU Bad = Off Cached I/O = Off VD PowerSave Policy = Controller Defined Default spin down time (mins) = 30 Coercion Mode = 1 GB ZCR Config = Unknown Max Chained Enclosures = 16 Direct PD Mapping = No Restore Hot Spare on Insertion = No Expose Enclosure Devices = Yes Maintain PD Fail History = Yes Zero Based Enclosure Enumeration = No Disable Puncturing = Yes EnableLDBBM = No Un-Certified Hard Disk Drives = Allow SMART Mode = Mode 6 Enable LED Header = No LED Show Drive Activity = Yes Dirty LED Shows Drive Activity = No EnableCrashDump = Yes Disable Online Controller Reset = No Treat Single span R1E as R10 = No Power Saving Option part number = Disabled TTY Log In Flash = No Auto Enhanced Import = Yes BreakMirror RAID Support = Yes Disable Join Mirror = No Enable Shield State = Yes Time taken to detect CME = 60 sec Capabilities : ============ Supported Drives = SAS, SATA Boot Volume Supported = NO RAID Level Supported = RAID0, RAID1, RAID5, RAID00, RAID10, RAID50, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Enable JBOD = No Mix in Enclosure = Allowed Mix of SAS/SATA of HDD type in VD = Not Allowed Mix of SAS/SATA of SSD type in VD = Not Allowed Mix of SSD/HDD in VD = Not Allowed SAS Disable = No Max Arms Per VD = 32 Max Spans Per VD = 8 Max Arrays = 128 Max VD per array = 64 Max Number of VDs = 64 Max Parallel Commands = 928 Max SGE Count = 60 Max Data Transfer Size = 8192 sectors Max Strips PerIO = 128 Max Configurable CacheCade Size = 0 Min Strip Size = 64 KB Max Strip Size = 1.0 MB Scheduled Tasks : =============== Consistency Check Reoccurrence = 168 hrs Next Consistency check launch = 09/24/2016, 02:59:53 Patrol Read Reoccurrence = 168 hrs Next Patrol Read launch = 09/24/2016, 02:59:53 Battery learn Reoccurrence = 672 hrs Next Battery Learn = 10/06/2016, 14:28:32 OEMID = IBM Drive Groups = 1 TOPOLOGY : ======== -------------------------------------------------------------------------- DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace -------------------------------------------------------------------------- 0 - - - - RAID5 Optl N 4.087 TB dsbl N N none N 0 0 - - - RAID5 Optl N 4.087 TB dsbl N N none N 0 0 0 252:5 7 DRIVE Onln N 837.258 GB dsbl N N none - 0 0 1 252:4 8 DRIVE Onln N 837.258 GB dsbl N N none - 0 0 2 252:1 10 DRIVE Onln N 837.258 GB dsbl N N none - 0 0 3 252:6 11 DRIVE Onln N 837.258 GB dsbl N N none - 0 0 4 252:2 12 DRIVE Onln N 837.258 GB dsbl N N none - 0 0 5 252:3 13 DRIVE Onln N 837.258 GB dsbl N N none - -------------------------------------------------------------------------- DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present Virtual Drives = 1 VD LIST : ======= --------------------------------------------------------- DG/VD TYPE State Access Consist Cache sCC Size Name --------------------------------------------------------- 0/0 RAID5 Optl RW Yes RWBD - 4.087 TB --------------------------------------------------------- Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent| R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency Physical Drives = 7 PD LIST : ======= ------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp ------------------------------------------------------------------------- 252:0 9 GHS - 837.258 GB SAS HDD N N 512B ST900MM0168 U 252:1 10 Onln 0 837.258 GB SAS HDD N N 512B ST900MM0168 U 252:2 12 Onln 0 837.258 GB SAS HDD N N 512B AL14SEB090N U 252:3 13 Onln 0 837.258 GB SAS HDD N N 512B AL14SEB090N U 252:4 8 Onln 0 837.258 GB SAS HDD N N 512B AL14SEB090N U 252:5 7 Onln 0 837.258 GB SAS HDD N N 512B AL14SEB090N U 252:6 11 Onln 0 837.258 GB SAS HDD N N 512B AL14SEB090N U ------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded Cachevault_Info : =============== ------------------------------------ Model State Temp Mode MfgDate ------------------------------------ CVPM02 Optimal 28C - 2016/01/09 ------------------------------------