Generating detailed summary of the adapter, it may take a while to complete. CLI Version = 007.1324.0000.0000 June 1, 2020 Operating system = Windows Server 2016 Controller = 0 Status = Success Description = None Basics : ====== Controller = 0 Model = RAID 930-24i 4GB Flash Serial Number = SXXXXXXX5 Current Controller Date/Time = 03/10/2022, 08:12:41 Current System Date/time = 03/10/2022, 08:12:43 SAS Address = 500062b1002dd100 PCI Address = 00:86:00:00 Mfg Date = 11/13/17 Rework Date = 00/00/00 Revision No = 26005 Version : ======= Firmware Package Build = 50.0.1-0374 Firmware Version = 5.001.00-0805 CPLD Version = 05664-021 SBR Version = 260 Boot Block Version = 7.02.00.00-0015 Bios Version = 7.00.09.0_4.17.08.00_0x07001600 NVDATA Version = 4.1610.00-0093 Driver Name = megasas35.sys Driver Version = 7.705.08.00 Bus : === Vendor Id = 0x1000 Device Id = 0x16 SubVendor Id = 0x1D49 SubDevice Id = 0x603 Host Interface = PCI-E Device Interface = SAS-12G Bus Number = 134 Device Number = 0 Function Number = 0 Domain ID = 0 Pending Images in Flash : ======================= Image name = No pending images Status : ====== Controller Status = Optimal Memory Correctable Errors = 0 Memory Uncorrectable Errors = 0 ECC Bucket Count = 0 Any Offline VD Cache Preserved = No BBU Status = 0 PD Firmware Download in progress = No Support PD Firmware Download = Yes Lock Key Assigned = No Failed to get lock key on bootup = No Lock key has not been backed up = No Bios was not detected during boot = No Controller must be rebooted to complete security operation = No A rollback operation is in progress = No At least one PFK exists in NVRAM = No SSC Policy is WB = No Controller has booted into safe mode = No Controller shutdown required = No Supported Adapter Operations : ============================ Rebuild Rate = Yes CC Rate = Yes BGI Rate = Yes Reconstruct Rate = Yes Patrol Read Rate = Yes Alarm Control = No Cluster Support = No BBU = Yes Spanning = Yes Dedicated Hot Spare = Yes Revertible Hot Spares = Yes Foreign Config Import = Yes Self Diagnostic = Yes Allow Mixed Redundancy on Array = No Global Hot Spares = Yes Deny SCSI Passthrough = No Deny SMP Passthrough = No Deny STP Passthrough = No Support more than 8 Phys = Yes FW and Event Time in GMT = No Support Enhanced Foreign Import = Yes Support Enclosure Enumeration = Yes Support Allowed Operations = Yes Abort CC on Error = Yes Support Multipath = Yes Support Odd & Even Drive count in RAID1E = No Support Security = Yes Support Config Page Model = Yes Support the OCE without adding drives = Yes Support EKM = Yes Snapshot Enabled = No Support PFK = Yes Support PI = Yes Support LDPI Type1 = No Support LDPI Type2 = No Support LDPI Type3 = No Support Ld BBM Info = No Support Shield State = Yes Block SSD Write Disk Cache Change = Yes Support Suspend Resume BG ops = Yes Support Emergency Spares = Yes Support Set Link Speed = Yes Support Boot Time PFK Change = Yes Support JBOD = Yes Disable Online PFK Change = Yes Support Perf Tuning = Yes Support SSD PatrolRead = Yes Real Time Scheduler = Yes Support Reset Now = Yes Support Emulated Drives = Yes Headless Mode = Yes Dedicated HotSpares Limited = No Point In Time Progress = Yes Extended LD = Yes Support Uneven span = No Support Config Auto Balance = No Support Maintenance Mode = No Support Diagnostic results = Yes Support Ext Enclosure = No Support Sesmonitoring = Yes Support SecurityonJBOD = Yes Support ForceFlash = Yes Support DisableImmediateIO = Yes Support LargeIOSupport = No Support DrvActivityLEDSetting = Yes Support FlushWriteVerify = Yes Support CPLDUpdate = Yes Support ForceTo512e = Yes Support discardCacheDuringLDDelete = No Support JBOD Write cache = No Support Large QD Support = No Support Ctrl Info Extended = Yes Support IButton less = Yes Support AES Encryption Algorithm = No Support Encrypted MFC = Yes Support Snapdump = No Support Force Personality Change = No Support Dual Fw Image = No Support PSOC Update = No Support Secure Boot = No Support Debug Queue = Yes Support Least Latency Mode = Yes Support OnDemand Snapdump = No Support Clear Snapdump = No Support PHY current speed = No Support Lane current speed = No Support NVMe Width = No Support Lane DeviceType = No Support Extended Drive performance Monitoring = No Enterprise Key management : ========================= Capability = Supported Boot Agent = Available Configured = No Supported PD Operations : ======================= Force Online = Yes Force Offline = Yes Force Rebuild = Yes Deny Force Failed = No Deny Force Good/Bad = No Deny Missing Replace = No Deny Clear = No Deny Locate = No Support Power State = No Set Power State For Cfg = No Support T10 Power State = No Support Temperature = Yes NCQ = Yes Support Max Rate SATA = No Support Degraded Media = No Support Parallel FW Update = No Support Drive Crypto Erase = No Support SSD Wear Gauge = No Supported VD Operations : ======================= Read Policy = Yes Write Policy = Yes IO Policy = Yes Access Policy = Yes Disk Cache Policy = Yes Reconstruction = Yes Deny Locate = No Deny CC = No Allow Ctrl Encryption = No Enable LDBBM = No Support FastPath = Yes Performance Metrics = Yes Power Savings = No Support Powersave Max With Cache = No Support Breakmirror = Yes Support SSC WriteBack = No Support SSC Association = No Support VD Hide = Yes Support VD Cachebypass = Yes Support VD discardCacheDuringLDDelete = No Support VD Scsi Unmap = No Advanced Software Option : ======================== ----------------------------------------- Adv S/W Opt Time Remaining Mode ----------------------------------------- MegaRAID FastPath Unlimited - MegaRAID SafeStore Unlimited - MegaRAID RAID6 Unlimited - MegaRAID RAID5 Unlimited - ----------------------------------------- Safe ID = EQ3WU1IHBBI8L3V6GDNIX997S9G36M1NXE7T9URZ HwCfg : ===== ChipRevision = B0 BatteryFRU = N/A Front End Port Count = 0 Backend Port Count = 8 BBU = Present Alarm = Missing Serial Debugger = Present NVRAM Size = 128KB Flash Size = 16MB On Board Memory Size = 4096MB CacheVault Flash Size = 8.187 GB TPM = Absent Upgrade Key = Absent On Board Expander = Absent Temperature Sensor for ROC = Present Temperature Sensor for Controller = Absent Upgradable CPLD = Present Upgradable PSOC = Absent Current Size of CacheCade (GB) = 0 Current Size of FW Cache (MB) = 3183 ROC temperature(Degree Celsius) = 69 Policies : ======== Policies Table : ============== ------------------------------------------------ Policy Current Default ------------------------------------------------ Predictive Fail Poll Interval 300 sec Interrupt Throttle Active Count 16 Interrupt Throttle Completion 50 us Rebuild Rate 30 % 30% PR Rate 30 % 30% BGI Rate 30 % 30% Check Consistency Rate 30 % 30% Reconstruction Rate 30 % 30% Cache Flush Interval 4s ------------------------------------------------ Flush Time(Default) = 4s Drive Coercion Mode = 1GB Auto Rebuild = On Battery Warning = On ECC Bucket Size = 15 ECC Bucket Leak Rate (hrs) = 24 Restore Hot Spare on Insertion = Off Expose Enclosure Devices = On Maintain PD Fail History = On Reorder Host Requests = On Auto detect BackPlane = SGPIO/i2c SEP Load Balance Mode = Auto Security Key Assigned = Off Disable Online Controller Reset = Off Use drive activity for locate = Off Boot : ==== BIOS Enumerate VDs = 1 Stop BIOS on Error = On Delay during POST = 0 Spin Down Mode = None Enable Ctrl-R = No Enable Web BIOS = No Enable PreBoot CLI = No Enable BIOS = Yes Max Drives to Spinup at One Time = 2 Maximum number of direct attached drives to spin up in 1 min = 60 Delay Among Spinup Groups (sec) = 2 Allow Boot with Preserved Cache = Off High Availability : ================= Topology Type = None Cluster Permitted = No Cluster Active = No Defaults : ======== Phy Polarity = 0 Phy PolaritySplit = 0 Strip Size = 256 KB Write Policy = WB Read Policy = No Read Ahead Cache When BBU Bad = Off Cached IO = Off VD PowerSave Policy = Controller Defined Default spin down time (mins) = 30 Coercion Mode = 1 GB ZCR Config = Unknown Max Chained Enclosures = 3 Direct PD Mapping = No Restore Hot Spare on Insertion = No Expose Enclosure Devices = Yes Maintain PD Fail History = Yes Zero Based Enclosure Enumeration = No Disable Puncturing = Yes EnableLDBBM = No DisableHII = No Un-Certified Hard Disk Drives = Allow SMART Mode = Mode 6 Enable LED Header = No LED Show Drive Activity = Yes Dirty LED Shows Drive Activity = No EnableCrashDump = Yes Disable Online Controller Reset = No Treat Single span R1E as R10 = No Power Saving option = Disabled TTY Log In Flash = No Auto Enhanced Import = Yes BreakMirror RAID Support = single span R1 Disable Join Mirror = No Enable Shield State = Yes Time taken to detect CME = 60 sec Capabilities : ============ Supported Drives = SAS, SATA RAID Level Supported = RAID0, RAID1(2 or more drives), RAID5, RAID6, RAID00, RAID10(2 or more drives per span), RAID50, RAID60 Enable JBOD = No Mix in Enclosure = Allowed Mix of SAS/SATA of HDD type in VD = Not Allowed Mix of SAS/SATA of SSD type in VD = Not Allowed Mix of SSD/HDD in VD = Not Allowed SAS Disable = No Max Arms Per VD = 32 Max Spans Per VD = 8 Max Arrays = 128 Max VD per array = 64 Max Number of VDs = 64 Max Parallel Commands = 4077 Max SGE Count = 60 Max Data Transfer Size = 8192 sectors Max Strips PerIO = 42 Max Configurable CacheCade Size(GB) = 0 Max Transportable DGs = 0 Enable Snapdump = No Enable SCSI Unmap = Yes FDE Drive Mix Support = No Min Strip Size = 64 KB Max Strip Size = 1.000 MB Scheduled Tasks : =============== Consistency Check Reoccurrence = 168 hrs Next Consistency check launch = 03/12/2022, 03:00:00 Patrol Read Reoccurrence = 168 hrs Next Patrol Read launch = 03/12/2022, 03:00:00 Battery learn Reoccurrence = 670 hrs Next Battery Learn = 03/27/2022, 10:00:00 OEMID = Lenovo Drive Groups = 2 TOPOLOGY : ======== ------------------------------------------------------------------------------ DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR ------------------------------------------------------------------------------ 0 - - - - RAID1 Optl N 893.137 GB dflt N N dflt N N 0 0 - - - RAID1 Optl N 893.137 GB dflt N N dflt N N 0 0 0 65:0 46 DRIVE Onln N 893.137 GB dflt N N dflt - N 0 0 1 65:1 47 DRIVE Onln N 893.137 GB dflt N N dflt - N 1 - - - - RAID10 Optl N 10.904 TB dsbl N N dflt N N 1 0 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N 1 0 0 65:2 49 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 0 1 65:3 41 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 0 2 65:4 40 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 0 3 65:5 44 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 1 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N 1 1 0 65:6 39 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 1 1 65:7 43 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 1 2 65:8 37 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 1 3 65:9 36 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 2 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N 1 2 0 65:10 35 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 2 1 65:11 42 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 2 2 65:12 34 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 2 3 65:13 33 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 3 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N 1 3 0 65:14 31 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 3 1 65:15 30 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 3 2 65:16 38 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 3 3 65:17 27 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 4 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N 1 4 0 65:18 28 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 4 1 65:19 26 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 4 2 65:20 25 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 4 3 65:21 32 DRIVE Onln N 1.089 TB dsbl N N dflt - N 1 - - 65:23 29 DRIVE DHS - 1.089 TB - - - - - N ------------------------------------------------------------------------------ DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present TR=Transport Ready Virtual Drives = 2 VD LIST : ======= ------------------------------------------------------------------- DG/VD TYPE State Access Consist Cache Cac sCC Size Name ------------------------------------------------------------------- 0/0 RAID1 Optl RW Yes RWBD - ON 893.137 GB OS 1/1 RAID10 Optl RW Yes RWBD - ON 10.904 TB Volume1 ------------------------------------------------------------------- VD=Virtual Drive| DG=Drive Group|Rec=Recovery Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked| Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack| AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled Check Consistency Physical Drives = 24 PD LIST : ======= ----------------------------------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ----------------------------------------------------------------------------------------------------- 65:0 46 Onln 0 893.137 GB SATA SSD N N 512B MTFDDAK960TDC-1AT1ZA 01PE307D7A09592LEN U - 65:1 47 Onln 0 893.137 GB SATA SSD N N 512B MTFDDAK960TDC-1AT1ZA 01PE307D7A09592LEN U - 65:2 49 Onln 1 1.089 TB SAS HDD N N 512B ST1200MM0009 U - 65:3 41 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:4 40 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:5 44 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:6 39 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:7 43 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:8 37 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:9 36 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:10 35 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:11 42 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:12 34 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:13 33 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:14 31 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:15 30 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:16 38 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:17 27 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:18 28 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:19 26 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:20 25 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:21 32 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - 65:22 48 UGood - 1.089 TB SAS HDD N N 512B ST1200MM0009 U - 65:23 29 DHS 1 1.089 TB SAS HDD N N 512B AL15SEB120N U - ----------------------------------------------------------------------------------------------------- EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded UBUnsp=UBad Unsupported|Rbld=Rebuild Enclosures = 2 Enclosure LIST : ============== ----------------------------------------------------------------------- EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific ----------------------------------------------------------------------- 65 OK 24 24 0 0 0 0 0 SAS35x36R exp-0.3.2.0 134 OK 8 0 0 0 0 0 1 - SGPIO ----------------------------------------------------------------------- EID=Enclosure Device ID |PD=Physical drive count |PS=Power Supply count| TSs=Temperature sensor count |Alms=Alarm count |SIM=SIM Count ||ProdID=Product ID Cachevault_Info : =============== ------------------------------------ Model State Temp Mode MfgDate ------------------------------------ CVPM02 Optimal 29C - 2018/04/05 ------------------------------------