smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.78-2-pve] (local build)
|
||
|
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||
|
|
||
|
=== START OF INFORMATION SECTION ===
|
||
|
Model Family: Western Digital Red
|
||
|
Device Model: WDC WD20EFRX-68AX9N0
|
||
|
Serial Number: WD-WMC300654321
|
||
|
LU WWN Device Id: 5 0014ee 058d123a4
|
||
|
Firmware Version: 80.00A80
|
||
|
User Capacity: 2.000.398.934.016 bytes [2,00 TB]
|
||
|
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||
|
Device is: In smartctl database [for details use: -P show]
|
||
|
ATA Version is: ACS-2 (minor revision not indicated)
|
||
|
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||
|
Local Time is: Wed Dec 23 12:45:04 2020 CET
|
||
|
SMART support is: Available - device has SMART capability.
|
||
|
SMART support is: Enabled
|
||
|
|
||
|
=== START OF READ SMART DATA SECTION ===
|
||
|
SMART Status not supported: ATA return descriptor not supported by controller firmware
|
||
|
SMART overall-health self-assessment test result: PASSED
|
||
|
Warning: This result is based on an Attribute check.
|
||
|
|
||
|
General SMART Values:
|
||
|
Offline data collection status: (0x00) Offline data collection activity
|
||
|
was never started.
|
||
|
Auto Offline Data Collection: Disabled.
|
||
|
Self-test execution status: ( 0) The previous self-test routine completed
|
||
|
without error or no self-test has ever
|
||
|
been run.
|
||
|
Total time to complete Offline
|
||
|
data collection: (26280) seconds.
|
||
|
Offline data collection
|
||
|
capabilities: (0x7b) SMART execute Offline immediate.
|
||
|
Auto Offline data collection on/off support.
|
||
|
Suspend Offline collection upon new
|
||
|
command.
|
||
|
Offline surface scan supported.
|
||
|
Self-test supported.
|
||
|
Conveyance Self-test supported.
|
||
|
Selective Self-test supported.
|
||
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
||
|
power-saving mode.
|
||
|
Supports SMART auto save timer.
|
||
|
Error logging capability: (0x01) Error logging supported.
|
||
|
General Purpose Logging supported.
|
||
|
Short self-test routine
|
||
|
recommended polling time: ( 2) minutes.
|
||
|
Extended self-test routine
|
||
|
recommended polling time: ( 266) minutes.
|
||
|
Conveyance self-test routine
|
||
|
recommended polling time: ( 5) minutes.
|
||
|
SCT capabilities: (0x70bd) SCT Status supported.
|
||
|
SCT Error Recovery Control supported.
|
||
|
SCT Feature Control supported.
|
||
|
SCT Data Table supported.
|
||
|
|
||
|
SMART Attributes Data Structure revision number: 16
|
||
|
Vendor Specific SMART Attributes with Thresholds:
|
||
|
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||
|
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
|
||
|
3 Spin_Up_Time 0x0027 174 173 021 Pre-fail Always - 4266
|
||
|
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 657
|
||
|
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
|
||
|
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
|
||
|
9 Power_On_Hours 0x0032 005 005 000 Old_age Always - 69539
|
||
|
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||
|
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||
|
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 657
|
||
|
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 655
|
||
|
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 1
|
||
|
194 Temperature_Celsius 0x0022 123 106 000 Old_age Always - 24
|
||
|
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
|
||
|
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
|
||
|
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
|
||
|
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
|
||
|
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0
|
||
|
|
||
|
SMART Error Log Version: 1
|
||
|
ATA Error Count: 323 (device log contains only the most recent five errors)
|
||
|
CR = Command Register [HEX]
|
||
|
FR = Features Register [HEX]
|
||
|
SC = Sector Count Register [HEX]
|
||
|
SN = Sector Number Register [HEX]
|
||
|
CL = Cylinder Low Register [HEX]
|
||
|
CH = Cylinder High Register [HEX]
|
||
|
DH = Device/Head Register [HEX]
|
||
|
DC = Device Command Register [HEX]
|
||
|
ER = Error register [HEX]
|
||
|
ST = Status register [HEX]
|
||
|
Powered_Up_Time is measured from power on, and printed as
|
||
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||
|
|
||
|
Error 323 occurred at disk power-on lifetime: 3990 hours (166 days + 6 hours)
|
||
|
When the command that caused the error occurred, the device was active or idle.
|
||
|
|
||
|
After command completion occurred, registers were:
|
||
|
ER ST SC SN CL CH DH
|
||
|
-- -- -- -- -- -- --
|
||
|
04 61 0c 00 00 00 00 Device Fault; Error: ABRT
|
||
|
|
||
|
Commands leading to the command that caused the error were:
|
||
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:52.646 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:52.646 CHECK POWER MODE
|
||
|
ec 00 00 00 00 00 00 00 6d+22:51:52.645 IDENTIFY DEVICE
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:52.396 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:52.396 CHECK POWER MODE
|
||
|
|
||
|
Error 322 occurred at disk power-on lifetime: 3990 hours (166 days + 6 hours)
|
||
|
When the command that caused the error occurred, the device was active or idle.
|
||
|
|
||
|
After command completion occurred, registers were:
|
||
|
ER ST SC SN CL CH DH
|
||
|
-- -- -- -- -- -- --
|
||
|
04 61 0c 00 00 00 00 Device Fault; Error: ABRT
|
||
|
|
||
|
Commands leading to the command that caused the error were:
|
||
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:52.396 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:52.396 CHECK POWER MODE
|
||
|
ec 00 00 00 00 00 00 00 6d+22:51:52.396 IDENTIFY DEVICE
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:52.146 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:52.146 CHECK POWER MODE
|
||
|
|
||
|
Error 321 occurred at disk power-on lifetime: 3990 hours (166 days + 6 hours)
|
||
|
When the command that caused the error occurred, the device was active or idle.
|
||
|
|
||
|
After command completion occurred, registers were:
|
||
|
ER ST SC SN CL CH DH
|
||
|
-- -- -- -- -- -- --
|
||
|
04 61 0c 00 00 00 00 Device Fault; Error: ABRT
|
||
|
|
||
|
Commands leading to the command that caused the error were:
|
||
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:52.146 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:52.146 CHECK POWER MODE
|
||
|
ec 00 00 00 00 00 00 00 6d+22:51:52.146 IDENTIFY DEVICE
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:51.896 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:51.896 CHECK POWER MODE
|
||
|
|
||
|
Error 320 occurred at disk power-on lifetime: 3990 hours (166 days + 6 hours)
|
||
|
When the command that caused the error occurred, the device was active or idle.
|
||
|
|
||
|
After command completion occurred, registers were:
|
||
|
ER ST SC SN CL CH DH
|
||
|
-- -- -- -- -- -- --
|
||
|
04 61 0c 00 00 00 00 Device Fault; Error: ABRT
|
||
|
|
||
|
Commands leading to the command that caused the error were:
|
||
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:51.896 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:51.896 CHECK POWER MODE
|
||
|
ec 00 00 00 00 00 00 00 6d+22:51:51.896 IDENTIFY DEVICE
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:51.647 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:51.647 CHECK POWER MODE
|
||
|
|
||
|
Error 319 occurred at disk power-on lifetime: 3990 hours (166 days + 6 hours)
|
||
|
When the command that caused the error occurred, the device was active or idle.
|
||
|
|
||
|
After command completion occurred, registers were:
|
||
|
ER ST SC SN CL CH DH
|
||
|
-- -- -- -- -- -- --
|
||
|
04 61 0c 00 00 00 00 Device Fault; Error: ABRT
|
||
|
|
||
|
Commands leading to the command that caused the error were:
|
||
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:51.647 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:51.647 CHECK POWER MODE
|
||
|
ec 00 00 00 00 00 00 00 6d+22:51:51.647 IDENTIFY DEVICE
|
||
|
ef 03 0c 00 00 00 00 00 6d+22:51:51.647 SET FEATURES [Set transfer mode]
|
||
|
e5 00 00 00 00 00 00 00 6d+22:51:51.647 CHECK POWER MODE
|
||
|
|
||
|
SMART Self-test log structure revision number 1
|
||
|
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||
|
|
||
|
SMART Selective self-test log data structure revision number 1
|
||
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||
|
1 0 0 Not_testing
|
||
|
2 0 0 Not_testing
|
||
|
3 0 0 Not_testing
|
||
|
4 0 0 Not_testing
|
||
|
5 0 0 Not_testing
|
||
|
Selective self-test flags (0x0):
|
||
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
||
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|