Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.1324.0000.0000 June 1, 2020
Operating system = Windows Server 2016
Controller = 0
Status = Success
Description = None
Basics :
======
Controller = 0
Model = RAID 930-24i 4GB Flash
Serial Number = SXXXXXXX5
Current Controller Date/Time = 03/10/2022, 08:12:41
Current System Date/time = 03/10/2022, 08:12:43
SAS Address = 500062b1002dd100
PCI Address = 00:86:00:00
Mfg Date = 11/13/17
Rework Date = 00/00/00
Revision No = 26005
Version :
=======
Firmware Package Build = 50.0.1-0374
Firmware Version = 5.001.00-0805
CPLD Version = 05664-021
SBR Version = 260
Boot Block Version = 7.02.00.00-0015
Bios Version = 7.00.09.0_4.17.08.00_0x07001600
NVDATA Version = 4.1610.00-0093
Driver Name = megasas35.sys
Driver Version = 7.705.08.00
Bus :
===
Vendor Id = 0x1000
Device Id = 0x16
SubVendor Id = 0x1D49
SubDevice Id = 0x603
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 134
Device Number = 0
Function Number = 0
Domain ID = 0
Pending Images in Flash :
=======================
Image name = No pending images
Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 0
PD Firmware Download in progress = No
Support PD Firmware Download = Yes
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No
Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruct Rate = Yes
Patrol Read Rate = Yes
Alarm Control = No
Cluster Support = No
BBU = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = Yes
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = Yes
Snapshot Enabled = No
Support PFK = Yes
Support PI = Yes
Support LDPI Type1 = No
Support LDPI Type2 = No
Support LDPI Type3 = No
Support Ld BBM Info = No
Support Shield State = Yes
Block SSD Write Disk Cache Change = Yes
Support Suspend Resume BG ops = Yes
Support Emergency Spares = Yes
Support Set Link Speed = Yes
Support Boot Time PFK Change = Yes
Support JBOD = Yes
Disable Online PFK Change = Yes
Support Perf Tuning = Yes
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = Yes
Extended LD = Yes
Support Uneven span = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = Yes
Support Ext Enclosure = No
Support Sesmonitoring = Yes
Support SecurityonJBOD = Yes
Support ForceFlash = Yes
Support DisableImmediateIO = Yes
Support LargeIOSupport = No
Support DrvActivityLEDSetting = Yes
Support FlushWriteVerify = Yes
Support CPLDUpdate = Yes
Support ForceTo512e = Yes
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = Yes
Support IButton less = Yes
Support AES Encryption Algorithm = No
Support Encrypted MFC = Yes
Support Snapdump = No
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = No
Support Secure Boot = No
Support Debug Queue = Yes
Support Least Latency Mode = Yes
Support OnDemand Snapdump = No
Support Clear Snapdump = No
Support PHY current speed = No
Support Lane current speed = No
Support NVMe Width = No
Support Lane DeviceType = No
Support Extended Drive performance Monitoring = No
Enterprise Key management :
=========================
Capability = Supported
Boot Agent = Available
Configured = No
Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = No
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = Yes
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Support SSD Wear Gauge = No
Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = No
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = Yes
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = Yes
Support VD Cachebypass = Yes
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = No
Advanced Software Option :
========================
-----------------------------------------
Adv S/W Opt Time Remaining Mode
-----------------------------------------
MegaRAID FastPath Unlimited -
MegaRAID SafeStore Unlimited -
MegaRAID RAID6 Unlimited -
MegaRAID RAID5 Unlimited -
-----------------------------------------
Safe ID = EQ3WU1IHBBI8L3V6GDNIX997S9G36M1NXE7T9URZ
HwCfg :
=====
ChipRevision = B0
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = Missing
Serial Debugger = Present
NVRAM Size = 128KB
Flash Size = 16MB
On Board Memory Size = 4096MB
CacheVault Flash Size = 8.187 GB
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Absent
Upgradable CPLD = Present
Upgradable PSOC = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 3183
ROC temperature(Degree Celsius) = 69
Policies :
========
Policies Table :
==============
------------------------------------------------
Policy Current Default
------------------------------------------------
Predictive Fail Poll Interval 300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion 50 us
Rebuild Rate 30 % 30%
PR Rate 30 % 30%
BGI Rate 30 % 30%
Check Consistency Rate 30 % 30%
Reconstruction Rate 30 % 30%
Cache Flush Interval 4s
------------------------------------------------
Flush Time(Default) = 4s
Drive Coercion Mode = 1GB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = On
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off
Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 2
Maximum number of direct attached drives to spin up in 1 min = 60
Delay Among Spinup Groups (sec) = 2
Allow Boot with Preserved Cache = Off
High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No
Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 256 KB
Write Policy = WB
Read Policy = No Read Ahead
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 1 GB
ZCR Config = Unknown
Max Chained Enclosures = 3
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = Yes
Zero Based Enclosure Enumeration = No
Disable Puncturing = Yes
EnableLDBBM = No
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = Yes
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving option = Disabled
TTY Log In Flash = No
Auto Enhanced Import = Yes
BreakMirror RAID Support = single span R1
Disable Join Mirror = No
Enable Shield State = Yes
Time taken to detect CME = 60 sec
Capabilities :
============
Supported Drives = SAS, SATA
RAID Level Supported = RAID0, RAID1(2 or more drives), RAID5, RAID6, RAID00, RAID10(2 or more drives per span), RAID50, RAID60
Enable JBOD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Not Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 64
Max Number of VDs = 64
Max Parallel Commands = 4077
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 42
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Enable Snapdump = No
Enable SCSI Unmap = Yes
FDE Drive Mix Support = No
Min Strip Size = 64 KB
Max Strip Size = 1.000 MB
Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = 03/12/2022, 03:00:00
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 03/12/2022, 03:00:00
Battery learn Reoccurrence = 670 hrs
Next Battery Learn = 03/27/2022, 10:00:00
OEMID = Lenovo
Drive Groups = 2
TOPOLOGY :
========
------------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
------------------------------------------------------------------------------
0 - - - - RAID1 Optl N 893.137 GB dflt N N dflt N N
0 0 - - - RAID1 Optl N 893.137 GB dflt N N dflt N N
0 0 0 65:0 46 DRIVE Onln N 893.137 GB dflt N N dflt - N
0 0 1 65:1 47 DRIVE Onln N 893.137 GB dflt N N dflt - N
1 - - - - RAID10 Optl N 10.904 TB dsbl N N dflt N N
1 0 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 0 0 65:2 49 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 0 1 65:3 41 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 0 2 65:4 40 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 0 3 65:5 44 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 1 0 65:6 39 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 1 65:7 43 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 2 65:8 37 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 3 65:9 36 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 2 0 65:10 35 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 1 65:11 42 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 2 65:12 34 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 3 65:13 33 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 3 0 65:14 31 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 1 65:15 30 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 2 65:16 38 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 3 65:17 27 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 4 0 65:18 28 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 1 65:19 26 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 2 65:20 25 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 3 65:21 32 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 - - 65:23 29 DRIVE DHS - 1.089 TB - - - - - N
------------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 2
VD LIST :
=======
-------------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-------------------------------------------------------------------
0/0 RAID1 Optl RW Yes RWBD - ON 893.137 GB OS
1/1 RAID10 Optl RW Yes RWBD - ON 10.904 TB Volume1
-------------------------------------------------------------------
VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 24
PD LIST :
=======
-----------------------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-----------------------------------------------------------------------------------------------------
65:0 46 Onln 0 893.137 GB SATA SSD N N 512B MTFDDAK960TDC-1AT1ZA 01PE307D7A09592LEN U -
65:1 47 Onln 0 893.137 GB SATA SSD N N 512B MTFDDAK960TDC-1AT1ZA 01PE307D7A09592LEN U -
65:2 49 Onln 1 1.089 TB SAS HDD N N 512B ST1200MM0009 U -
65:3 41 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:4 40 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:5 44 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:6 39 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:7 43 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:8 37 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:9 36 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:10 35 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:11 42 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:12 34 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:13 33 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:14 31 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:15 30 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:16 38 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:17 27 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:18 28 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:19 26 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:20 25 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:21 32 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:22 48 UGood - 1.089 TB SAS HDD N N 512B ST1200MM0009 U -
65:23 29 DHS 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
-----------------------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
Enclosures = 2
Enclosure LIST :
==============
-----------------------------------------------------------------------
EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific
-----------------------------------------------------------------------
65 OK 24 24 0 0 0 0 0 SAS35x36R exp-0.3.2.0
134 OK 8 0 0 0 0 0 1 - SGPIO
-----------------------------------------------------------------------
EID=Enclosure Device ID |PD=Physical drive count |PS=Power Supply count|
TSs=Temperature sensor count |Alms=Alarm count |SIM=SIM Count ||ProdID=Product ID
Cachevault_Info :
===============
------------------------------------
Model State Temp Mode MfgDate
------------------------------------
CVPM02 Optimal 29C - 2018/04/05
------------------------------------